NEWS AND EVENTS
17.05.2012
Interview with Elena Turanskaya at Metering Asia 2012
more
05.04.2012
ADD GRUP participates at African Utility Week 2012
more
21.03.2012
Meet us at Metering, Billing/CRM Asia 2012 8-9 May, Bangkok
more
|
ADDAX Equipment
| |  | SINGLE-PHASE METER accuracy class 1.0; reference/maximum current 10/80 А; precision shunt used as a current sensor; multi-tariff metering; non-volatile memory and archive; data accumulation over specified time periods; consumption management (240V/100A relay); data exchange via PL LV (PL-modem); differential current sensor; protection from overheating, overcurrent and bad voltage; operating temperature range from minus 40°C to +70°C. | | | Back on Top | | |  | SINGLE-PHASE POLE METER accuracy class 1.0; reference/maximum current 10/60 А; precision shunt as a current sensor; multi-tariff metering; non-volatile memory and archive; data accumulation over specified time periods; data exchange via PL 0.4 kV (PL-modem); protection from overheating, overcurrent and bad voltage; operating temperature range from minus 40°C to +70°C. | | | Back on Top | | |  | THREE-PHASE DIRECT-CONNECTED METER accuracy class on active/reactive energy 1.0/2.0; reference/maximum current 10/80 А; current transformer used as a current sensor; multi-tariff metering; non-volatile memory and archive; data accumulation over specified time periods; consumption management (240V/100A and 240V/15A relays); data exchange via 0.4 kV PL (PL-modem); differential current sensor; protection from overheating, overcurrent and bad voltage; operating temperature range from minus 40°C to +70°C. | | | Back on Top | | |  | THREE-PHASE TRANSFORMER-CONNECTED METER accuracy class on active/reactive energy 0.5S/1.0; reference/maximum current 5/10 А; current transformer used as current sensor; multi-tariff metering; non-volatile memory and archive; data accumulation over specified time periods; data exchange via 0.4 kV PL (PL-modem); protection from overheating, overcurrent and bad voltage ; operating temperature range from minus 40°C to +70°C. | | | Back on Top | | |  | USER DISPLAY metering data displaying; operating voltages of 110/220-240 V; special screen; PL-modem. | | | Back on Top | | |  | ROUTER communication support and data storage; 0.5/8 Mb size non-volatile memory; built-in timer with autonomic supply from a lithium battery; timer error not more than ± 5 s; operating voltages range 180 - 440 V; interfaces for PL LV, PL MV, CM.Bus, M.Bus, RF, Ethernet, GSM/SMS data transmission rate via PL 300/4000 baud; operating temperature range from minus 40°С to +60°С. | | | Back on Top | | |  | COUPLING UNIT capacitive reference voltage 12/24 kV; impedance from line side 400 Ω; impedance from equipment side 75 Ω | | | Back on Top | | |  | AIU - ADDAX Interface Unit 4 channels: pulse output or digital interface Local RF or M-BUS Optical port Cumulative sum metering via 4 channels Generation of daily consumption cards Non-volatile memory Alarm control | | | Back on Top | | |  | LIGHTING CONTROL UNIT (LCU) built-in single-phase meter; two channels (relay) for external load control; PL-modem | | | Back on Top | | |  | RML MONITOR Measuring device for signal/noise level in communication line. PL-modem | | | Back on Top | |
|
Our specialization
Quick links
|